Science Breakthrough: An in-body communication network enables seamless connectivity between wearables and implantable therapeutic devices

source:material synthesis Views:208time:2026-11-11material synthesis: 1092348845

已传文件:photo/1794360855.png

Networks of bioelectronic sensors and actuators enable closed-loop therapies to interface with remotely relevant physiological dynamics. Currently, device interactions are constrained by tissue-penetrating communication modalities that suffer from low transmission efficiency and require bulky components. Inspired by the ionic signaling of the nervous system, we engineered a communication platform that uses tissue as a conductive medium to relay signals between implants and wearables across epidermal, subcutaneous, intraperitoneal, and gastrointestinal compartments. The devices generate transient electric fields and selectively activate other units upon receiving pulses that trigger their dedicated transistor circuits. The injectable implants feature ultra-low power consumption during the listening state and deliver >10× greater tissue communication coverage compared with Bluetooth. In rat models, we demonstrate a coordinated whole-body network of sensors and neural interfaces that achieves wireless control of bilateral limb movement.

This study was published in Science under the title “An in-body networking system for communication between wearable and implantable therapeutics”.

Figure 1

In-body communication enables low-power networking of wearable and implantable therapeutic devices. (A) Overview of the Smart Wireless Autonomous Networking System (SWANS). (B) Example use case of SWANS: a wearable sensor detects forelimb movement to independently control hindlimb motion. (C and D) SWANS implant (dimensions: 3 mm × 1.1 mm × 17 mm). (E) Syringe-assisted implantation of the SWANS receiver into the subcutaneous space of a rat. (F and G) Theoretical (bar plots) and experimental (scatter points, mean ± s.d., n = 3 devices) power characteristics of implantable neuromodulation bioelectronics controlled via SWANS in-body ionic communication (IBC), near-field communication (NFC), and Bluetooth Low Energy (BLE). Battery lifetime was calculated using batteries matched to each platform (IBC: 26 mAh, 1.55 V; BLE: 20 mAh, 3.0 V; NFC: 20 mAh, 3.3 V). (H) Voltage measured across the transistor gate upon applying gradually increasing pulse voltages on ex vivo chicken breast tissue. Shaded region indicates the threshold voltage (black line: mean; gray lines: individual trials; n = 9 trials). (I) Insertion of a resistor (NPN-R) between the receiving pad and the base of the NPN transistor in ex vivo chicken breast samples increases the applied voltage required for switching (black line: mean; gray lines: individual trials; n = 10 trials).


Figure 2

In-body communication architecture. (A) A custom flexible printed circuit board (fPCB) continuously monitors strain sensors and automatically transmits variable (0 to 12 V) square-wave pulses to trigger the implantable network. Bioelectronic devices can be switched individually or in concert. (B) Block diagram for closed-loop control and monitoring of implantable actuators via in-body ionic communication. Components include an analog-to-digital converter (ADC), microcontroller unit (MCU), transmitter (TX), and receiver (RX). (C) Photograph of the wearable fPCB. (D) Photograph of stainless steel microneedles that allow signals from the wearable hub to bypass the stratum corneum (inset scale bar, 1 mm). (E) Photograph of the implantable fPCB with voltage-receiving pads and a nerve cuff. (F) Representative (4 V, 1 Hz, 1 ms) square-wave pulses generated in rats using microneedle electrodes with varying needle heights in contact with the skin. (G) Peak injected currents measured in rats using different skin-contact electrodes (n = 18 trials from three rats; standard deviation is plotted).

Figure 3

In-body IBC generates in vivo voltage gradients without inducing cellular damage. (A–C) Voltages measured across the transistor gate upon application of pulses with gradually increasing amplitudes on rat tissues in vivo. Receiving electrodes were placed subcutaneously (SQ) (A) or intraperitoneally (IP) (B) with an electrode separation of 2.5 cm; the transmitting and ground electrodes were positioned on the skin surface with a separation of 4 cm. In (C), receiving electrodes were placed intragastrically (IG) inside the stomach with a 1 cm separation. Shaded regions denote transistor gate voltage and threshold voltage [black lines: mean; gray lines: individual trials; (A) n = 27 trials across 3 rats, (B) n = 9 trials across 3 rats, (C) n = 10 trials from 1 rat]. (D) Peak received voltage at the in-body receiving electrode when the receiver was oriented at different angles relative to the wearable signal-injecting electrode (n = 5 trials from 1 rat). The receiving electrodes were implanted beneath the skin with a 2.5 cm spacing. Transmitting and ground electrodes were placed at various spatial locations on the skin surface, including aligned with the implant (blue), offset from the implant (purple), on the animal’s dorsal and ventral sides (pink), diagonally across the body (orange), and contralateral to the implant (green) (n = 5 trials; lines denote mean values).

Figure 4

Biointegrated electronic network for neural stimulation. (A) Schematic and photograph of a rat equipped with the SWANS neural stimulation system, alongside representative images of leg twitching from the resting state (translucent) to the flexed state (opaque). (B) The wearable circuit board outputs pulses of varying amplitude and width upon detection of stimulation on either forelimb, which activates distinct implants. (C) Current output from an NPN implant driven by high‑voltage short pulses; (D) current output from a PNP implant driven by low‑voltage short pulses; and (E) current output from an NPN + capacitor (NPN‑C) implant driven by longer medium‑voltage pulses. Points above the dashed line indicate leg flexion. (F) Simultaneous triggering of NPN and PNP implants in the same animal results in initial activation of only the PNP, followed by activation of both NPN and PNP as the voltage gradually increases.



Summary

To address the low efficiency and bulky hardware of trans‑tissue communication between implants and wearables, the authors drew inspiration from ionic signaling in the nervous system. They use biological tissue itself as a conductive medium. Transient electric fields and pulses are adopted to trigger dedicated transistor circuits, enabling selective activation among devices. The implants are injectable with ultra‑low power consumption during the listening state, offering more than an order‑of‑magnitude improvement in communication coverage compared with Bluetooth.


In rat models, the authors established a network of whole‑body sensors and neural interfaces to achieve wireless bilateral limb control. This demonstrates that the communication strategy can support linkage to remote physiological dynamics for closed‑loop therapies. Future directions worthy of attention include multi‑implant coordination, long‑term low‑power operation, biosafety evaluation and clinical translation.


Reference:

DOI: 10.1126/science.adz5300


We specialize in custom development of functional materials for nanomedicine. Materials can be tailored to experimental requirements with tunable structure, particle size and surface modification. A full suite of characterization services is provided. Research plans are iteratively optimized with continuous technical support. Our services cover targeted delivery, bioimaging, nanotheranostics and other research projects. Feel free to share your specifications for solution evaluation.

Mr. Zhang: +86 17715390137

Mr. Chen: +86 18914047343



 

Reminder: Beijing Beike New Material Technology Co., Ltd. supplies products only for scientific research, not for humans
All rights reserved © 2019 beijing beike new material Technology Co., Ltd 京ICP备16054715-2号
advisory
phone
Email:mxenes@163.com
Tel:+86-17715390137
scan

scan
WeChat